FUV-1800, FUV-1800PC,FUV-1600,FUV1600PC,FV-1800,FV-1800PC,FV-1600,FV-1600P
FAITHFUL
1.Large LCD screen(480*272 Dots)with 65 thousand true color and support U disk data saving.
2.Imported&Environmental Deuterlum lamp,proventing from Ozone inhalation.
3.Data output;Data can be exported to U disk (USB Output)
4.Print port:Instrument can connect PCL printing A4 paper (USB Port)
5.Adopted high-class grating with wholly hermetic light path design,to ensure the instrument has the super low stray light.
6.Upgrade package can be downloaded from AOE web with S/N,support U disk one-key upgrade
7.Real-tome monitoring the lifetime of Deuterium lamp and Tungsten lamp with advance system.
8.Pre-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system.
9.Wiht GLP self-check function,check the wavelength accuracy and Photometry accuracy,can provide test report and power-off protection.
1.Large LCD screen(480*272 Dots)with 65 thousand true color and support U disk data saving.
2.Imported&Environmental Deuterlum lamp,proventing from Ozone inhalation.
3.Data output;Data can be exported to U disk (USB Output)
4.Print port:Instrument can connect PCL printing A4 paper (USB Port)
5.Adopted high-class grating with wholly hermetic light path design,to ensure the instrument has the super low stray light.
6.Upgrade package can be downloaded from AOE web with S/N,support U disk one-key upgrade
7.Real-tome monitoring the lifetime of Deuterium lamp and Tungsten lamp with advance system.
8.Pre-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system.
9.Wiht GLP self-check function,check the wavelength accuracy and Photometry accuracy,can provide test report and power-off protection.
Model | FUV-1800 FUV-1800PC | FUV-1600 FUV1600PC | FV-1800 FV-1800PC | FV-1600 FV-1600PC |
Optical System | Single Beam,Grating 1200 lines/mm | |||
Wavelength Range | 190-1100nm | 320-1100nm | ||
Spectral Bandwidth | 2nm | 4nm | 2nm | 4nm |
Wavelength Accuracy | ±0.5nm | |||
Wavelength Repeatability | ≤0.2nm | |||
Photometric Accuracy | ±0.002A(0-0.Abs), ±0.004A(0.5-1.0Abs), ±0.5%T(0-100%T) | |||
Photometric Repeatability | 0.001Abs(0-0.5Abs), 0.002Abs(0.5-1.0Abs), ≤0.2%T (0-100%T) | |||
Stray Light | ≤0.04%T@360nm;220nm | ≤0.04%T@360nm | ||
Stability | ±0.001A/h@500nm | |||
Baseline Flatness | ±0.002A | |||
Noise | 0.0005A | |||
Display | 65 thousand ture color TFT LCD (480*272) | |||
Photometric Mode | T,A,C,E | |||
Photometric Range | 0-200% T,-0.301-3.0A | |||
Detector | Silicon Photodiode | |||
Light Source | Deuterium Lamp,Tungsten Lamp | |||
Input | Membrane Keypad | |||
Output | USB-A*2Print and data output USB-B Connect PC | |||
Compartment | Optional 8Auto Cell holder, Solid Sample Holder, Micro Cell Holder, 100mm Cell Holder |
Model | FUV-1800 FUV-1800PC | FUV-1600 FUV1600PC | FV-1800 FV-1800PC | FV-1600 FV-1600PC |
Optical System | Single Beam,Grating 1200 lines/mm | |||
Wavelength Range | 190-1100nm | 320-1100nm | ||
Spectral Bandwidth | 2nm | 4nm | 2nm | 4nm |
Wavelength Accuracy | ±0.5nm | |||
Wavelength Repeatability | ≤0.2nm | |||
Photometric Accuracy | ±0.002A(0-0.Abs), ±0.004A(0.5-1.0Abs), ±0.5%T(0-100%T) | |||
Photometric Repeatability | 0.001Abs(0-0.5Abs), 0.002Abs(0.5-1.0Abs), ≤0.2%T (0-100%T) | |||
Stray Light | ≤0.04%T@360nm;220nm | ≤0.04%T@360nm | ||
Stability | ±0.001A/h@500nm | |||
Baseline Flatness | ±0.002A | |||
Noise | 0.0005A | |||
Display | 65 thousand ture color TFT LCD (480*272) | |||
Photometric Mode | T,A,C,E | |||
Photometric Range | 0-200% T,-0.301-3.0A | |||
Detector | Silicon Photodiode | |||
Light Source | Deuterium Lamp,Tungsten Lamp | |||
Input | Membrane Keypad | |||
Output | USB-A*2Print and data output USB-B Connect PC | |||
Compartment | Optional 8Auto Cell holder, Solid Sample Holder, Micro Cell Holder, 100mm Cell Holder |