PH100,EC100,DO100,PC100,PD100,CD100,PCD100
FAITHFUL
High-res 7" display screen with white backlight, easy to read.
Automatic calibration, ATC measurement, parameter setup.
Automatic reading stable indication, calibration indication.
Data storage:450readings.
Data export: flash disk/ wireless printer (the printer is optional).
Equipped with a flexible probe holder and pH buffer solutions for convenient use.
Protection class: IP54.
High-res 7" display screen with white backlight, easy to read.
Automatic calibration, ATC measurement, parameter setup.
Automatic reading stable indication, calibration indication.
Data storage:450readings.
Data export: flash disk/ wireless printer (the printer is optional).
Equipped with a flexible probe holder and pH buffer solutions for convenient use.
Protection class: IP54.
Classic | single parameter | multi-parameter | |||||||
Model | PH100 | EC100 | DO100 | PC100 | PD100 | CD100 | PCD100 | ||
Parameter | pH/mV.℃ | √ | - | - | √ | √ | - | √ | |
mV(ORP).℃ | √ | - | - | √ | √ | - | √ | ||
Cond/TDS/Sal./Res.℃ | - | √ | - | √ | - | √ | √ | ||
DO.℃ | - | - | √ | - | √ | √ | √ | ||
pH | Measurement range | (-2.00 - 20.00)pH | √ | - | - | √ | √ | - | √ |
Resolution | 0.1/0.01 | √ | - | - | √ | √ | - | √ | |
Accuracy | ±0.01pH | √ | - | - | √ | √ | - | √ | |
Calibration points | 1-3 pts auto | √ | - | - | √ | √ | - | √ | |
AIC range | 0-100℃/(32.0-212.0)℉ | √ | - | - | √ | √ | - | √ | |
ORP | Measurement range | (-199.9-+199.9)mV | √ | - | - | √ | √ | - | √ |
Resolution | 0.1/1 | √ | - | - | √ | √ | - | √ | |
Accuracy | ±0.1%F.S±one digit | √ | - | - | √ | √ | - | √ | |
Conductivity | Measurement ranges | 0-200.0ms/cm. | - | √ | - | √ | - | √ | √ |
Calibration points | Ore point auto | - | √ | - | √ | - | √ | √ | |
Resolution | 0.001 | - | √ | - | √ | - | √ | √ | |
ATC range | (0.0-50.0)°C/(32.0-122.0)℉ auto | - | √ | - | √ | - | √ | √ | |
Accuracy | ±1.0% FS ±One digit | - | √ | - | √ | - | √ | √ | |
DO | Measurement range | (0.00-20.00)mg/L | - | - | √ | - | √ | √ | √ |
Accuracy | ±0.30 mg/L ±0ne digit | - | - | √ | - | √ | √ | √ | |
DO saturation | (0.00-200.0)% | - | - | √ | - | √ | √ | √ | |
Automatic barometric pressure compensation | (0- 200.0)kPa | - | - | √ | - | √ | √ | √ | |
Automatic temperature compensation | (0.0-50.0)℃/(32.0-122.0)°F | - | - | √ | - | √ | √ | √ | |
Manual salinity compensation | 0-45ppt | - | - | √ | - | √ | √ | √ | |
Temperature | Measurement range | (0.0-100.0)℃/(32.0-212.0)℉ | √ | √ | √ | √ | √ | √ | √ |
Accuracy | ±0.2℃ | √ | √ | √ | √ | √ | √ | √ | |
Others | Data export | USB Stick/Printer | √ | √ | √ | √ | √ | √ | √ |
Power supply | DC12V | √ | √ | √ | √ | √ | √ | √ | |
Test kit | Meter | √ | √ | √ | √ | √ | √ | √ | |
Plastic ATC pH probe 201T | √ | - | - | √ | √ | - | √ | ||
Plastic ATC Cond probe CON201T, K=1.0 | - | √ | - | √ | - | √ | √ | ||
Polarographic D0 probe DO01-2M, cable length:2m | - | - | √ | - | √ | √ | √ | ||
pH buffer solution:pH4.00/7.00/10.01, 50mL, one for each | √ | - | - | √ | √ | - | √ | ||
Standard Cond solution 84μS/1413pS/12.88mS/cm, 50mL, one for each | - | √ | - | √ | - | √ | √ | ||
Membrane refill solution DOS-01,30mL,1btl | - | - | √ | - | √ | √ | √ | ||
Membrane sensor caps DOSC: 3pcs/group,1pkg | - | - | √ | - | √ | √ | √ | ||
Power adaptor: 1pc | √ | √ | √ | √ | √ | √ | √ | ||
Flexible probe holder F01: 1pc | √ | √ | √ | √ | √ | √ | √ |
Classic | single parameter | multi-parameter | |||||||
Model | PH100 | EC100 | DO100 | PC100 | PD100 | CD100 | PCD100 | ||
Parameter | pH/mV.℃ | √ | - | - | √ | √ | - | √ | |
mV(ORP).℃ | √ | - | - | √ | √ | - | √ | ||
Cond/TDS/Sal./Res.℃ | - | √ | - | √ | - | √ | √ | ||
DO.℃ | - | - | √ | - | √ | √ | √ | ||
pH | Measurement range | (-2.00 - 20.00)pH | √ | - | - | √ | √ | - | √ |
Resolution | 0.1/0.01 | √ | - | - | √ | √ | - | √ | |
Accuracy | ±0.01pH | √ | - | - | √ | √ | - | √ | |
Calibration points | 1-3 pts auto | √ | - | - | √ | √ | - | √ | |
AIC range | 0-100℃/(32.0-212.0)℉ | √ | - | - | √ | √ | - | √ | |
ORP | Measurement range | (-199.9-+199.9)mV | √ | - | - | √ | √ | - | √ |
Resolution | 0.1/1 | √ | - | - | √ | √ | - | √ | |
Accuracy | ±0.1%F.S±one digit | √ | - | - | √ | √ | - | √ | |
Conductivity | Measurement ranges | 0-200.0ms/cm. | - | √ | - | √ | - | √ | √ |
Calibration points | Ore point auto | - | √ | - | √ | - | √ | √ | |
Resolution | 0.001 | - | √ | - | √ | - | √ | √ | |
ATC range | (0.0-50.0)°C/(32.0-122.0)℉ auto | - | √ | - | √ | - | √ | √ | |
Accuracy | ±1.0% FS ±One digit | - | √ | - | √ | - | √ | √ | |
DO | Measurement range | (0.00-20.00)mg/L | - | - | √ | - | √ | √ | √ |
Accuracy | ±0.30 mg/L ±0ne digit | - | - | √ | - | √ | √ | √ | |
DO saturation | (0.00-200.0)% | - | - | √ | - | √ | √ | √ | |
Automatic barometric pressure compensation | (0- 200.0)kPa | - | - | √ | - | √ | √ | √ | |
Automatic temperature compensation | (0.0-50.0)℃/(32.0-122.0)°F | - | - | √ | - | √ | √ | √ | |
Manual salinity compensation | 0-45ppt | - | - | √ | - | √ | √ | √ | |
Temperature | Measurement range | (0.0-100.0)℃/(32.0-212.0)℉ | √ | √ | √ | √ | √ | √ | √ |
Accuracy | ±0.2℃ | √ | √ | √ | √ | √ | √ | √ | |
Others | Data export | USB Stick/Printer | √ | √ | √ | √ | √ | √ | √ |
Power supply | DC12V | √ | √ | √ | √ | √ | √ | √ | |
Test kit | Meter | √ | √ | √ | √ | √ | √ | √ | |
Plastic ATC pH probe 201T | √ | - | - | √ | √ | - | √ | ||
Plastic ATC Cond probe CON201T, K=1.0 | - | √ | - | √ | - | √ | √ | ||
Polarographic D0 probe DO01-2M, cable length:2m | - | - | √ | - | √ | √ | √ | ||
pH buffer solution:pH4.00/7.00/10.01, 50mL, one for each | √ | - | - | √ | √ | - | √ | ||
Standard Cond solution 84μS/1413pS/12.88mS/cm, 50mL, one for each | - | √ | - | √ | - | √ | √ | ||
Membrane refill solution DOS-01,30mL,1btl | - | - | √ | - | √ | √ | √ | ||
Membrane sensor caps DOSC: 3pcs/group,1pkg | - | - | √ | - | √ | √ | √ | ||
Power adaptor: 1pc | √ | √ | √ | √ | √ | √ | √ | ||
Flexible probe holder F01: 1pc | √ | √ | √ | √ | √ | √ | √ |