FPC-L3
FAITHFUL
FPC-L3 Oil Particle Counter,based on GB/T18854-2002-(ISO11171 -1999) standard. Use shading counting principle ,meeting international standard. Can respond with fast,precise,reliable and repeatable result and complete pollution monitoring analysis report, suitable to detect degree of contaminated particle in hydraulic oil, lubricating oil, fire-resistant fuel, insulating oil and turbine oil . Widely used in aviation, aerospace, electric power, petroleum, chemical, transportation, port, metallurgy, machinery, automobile manufacturing
FPC-L3 Oil Particle Counter,based on GB/T18854-2002-(ISO11171 -1999) standard. Use shading counting principle ,meeting international standard. Can respond with fast,precise,reliable and repeatable result and complete pollution monitoring analysis report, suitable to detect degree of contaminated particle in hydraulic oil, lubricating oil, fire-resistant fuel, insulating oil and turbine oil . Widely used in aviation, aerospace, electric power, petroleum, chemical, transportation, port, metallurgy, machinery, automobile manufacturing
Optical system : shading principle
Optical source: laser
Size range: 0.8μm-600μm
Channel number : 64
Sensitive : 0.8um(ISO4402)or 3um(c)(GB/T18854,ISO11171)
Resolution: <10%
Repeatability: RSD<2% Dynamic viscosity: ≤400 cSt
Sampling volume: 0.2-6000ml,0.1ml interval
Sampling speed range: 5ml/min-80ml/min
Sampling precision: ≤±0.5%
Barometric chamber : Barometric chamber combine positive pressure with negative pressure ,can remove the bubble in the sample, can test high viscoelastic sample
Max.negative pressure : -0.08MPa
Max.positive pressure : 0.8 MPa
Coincidence error limit: 12000-40000 particals/ml
Temperature collection T (Optional) :-40~100℃ ,Precision : ±0.5℃
Moisture (Optional) : aw:1~100%RH ,Precision :±1%RH AH:1~300ppm ,Precision :±10ppm
Dielectric constant (Optional) :1-6
Viscosity (Optional) : 0.5~50cP, Precision :±2%(>10cP),±0.2cP(<10cP)
Power : 110~245V AC、50Hz,70W
External Size : 340mm╳310mm╳730mm
NW:25kg
Optical system : shading principle
Optical source: laser
Size range: 0.8μm-600μm
Channel number : 64
Sensitive : 0.8um(ISO4402)or 3um(c)(GB/T18854,ISO11171)
Resolution: <10%
Repeatability: RSD<2% Dynamic viscosity: ≤400 cSt
Sampling volume: 0.2-6000ml,0.1ml interval
Sampling speed range: 5ml/min-80ml/min
Sampling precision: ≤±0.5%
Barometric chamber : Barometric chamber combine positive pressure with negative pressure ,can remove the bubble in the sample, can test high viscoelastic sample
Max.negative pressure : -0.08MPa
Max.positive pressure : 0.8 MPa
Coincidence error limit: 12000-40000 particals/ml
Temperature collection T (Optional) :-40~100℃ ,Precision : ±0.5℃
Moisture (Optional) : aw:1~100%RH ,Precision :±1%RH AH:1~300ppm ,Precision :±10ppm
Dielectric constant (Optional) :1-6
Viscosity (Optional) : 0.5~50cP, Precision :±2%(>10cP),±0.2cP(<10cP)
Power : 110~245V AC、50Hz,70W
External Size : 340mm╳310mm╳730mm
NW:25kg
冀ICP备18005191号 | Copyright © 2018 Faithful Instrument (Hebei) Co.,Ltd. All rights reserved.