MEASUREMENT PARAMETERS
Dissolved oxygen concentration,percent saturation of oxygen.
FEATURES
1 or 2 points calibration using the air-saturated water or zero oxygen solution.
Salinity and barometric pressure compensations improve the accuracy of measurement.
Automatic Temperature Compensation provides accurate reading over the entire range.
Auto-Hold feature senses and locks the measurement endpoint.
Manual temperature calibration corrects the temperature deviation.
Setup menu allows setting the 6 parameters, including the number of calibration points, temperature unit, concentration unit,etc.
Reset feature automatically resumes all settings back to factory default options.
MEASUREMENT PARAMETERS
Dissolved oxygen concentration,percent saturation of oxygen.
FEATURES
1 or 2 points calibration using the air-saturated water or zero oxygen solution.
Salinity and barometric pressure compensations improve the accuracy of measurement.
Automatic Temperature Compensation provides accurate reading over the entire range.
Auto-Hold feature senses and locks the measurement endpoint.
Manual temperature calibration corrects the temperature deviation.
Setup menu allows setting the 6 parameters, including the number of calibration points, temperature unit, concentration unit,etc.
Reset feature automatically resumes all settings back to factory default options.
Model | FPH810 | |
Do | Measuring Range | 0.0-20.0 mg/L |
Accuracy | ±0.5mg/L | |
Resolution | 0.1 mg/L | |
%Saturation | Measuring Range | 0.0-200.0% |
Accuracy | ±2.0% | |
Resolution | 0.1% | |
General | Temperature Compensation | 0~40℃,Automatic |
Barometric Pressure Correction | 60.0~112.5KPa,450~850mmHg,Manual | |
Salinity Correction | 0~35g/L,Manual | |
Hold Function | Manual or Automatic endpoint detection | |
Power Off | Manual or Automatic(3 hours after last key pressed) | |
Sensor Type | DO100 polarographic DO probe | |
Connector | 6-pin mini plug | |
Display | Custom LCD | |
Power Requirements | DC9V, using AC adapter,220VAC/50Hz | |
Dimension and Weight | 210(L)*205(W)*75(H)mm,1.5kg |
Model | FPH810 | |
Do | Measuring Range | 0.0-20.0 mg/L |
Accuracy | ±0.5mg/L | |
Resolution | 0.1 mg/L | |
%Saturation | Measuring Range | 0.0-200.0% |
Accuracy | ±2.0% | |
Resolution | 0.1% | |
General | Temperature Compensation | 0~40℃,Automatic |
Barometric Pressure Correction | 60.0~112.5KPa,450~850mmHg,Manual | |
Salinity Correction | 0~35g/L,Manual | |
Hold Function | Manual or Automatic endpoint detection | |
Power Off | Manual or Automatic(3 hours after last key pressed) | |
Sensor Type | DO100 polarographic DO probe | |
Connector | 6-pin mini plug | |
Display | Custom LCD | |
Power Requirements | DC9V, using AC adapter,220VAC/50Hz | |
Dimension and Weight | 210(L)*205(W)*75(H)mm,1.5kg |
冀ICP备18005191号 | Copyright © 2018 Faithful Instrument (Hebei) Co.,Ltd. All rights reserved.