FPC-L2 Oil Liquid Particle Counter

Product Description

International Hydraulic Standards Committee;

High-precision laser sensor, wide test range, stable performance, low noise andhigh resolution;

Using high-pressure syringe pump sampling method, the sampling volume can beset by oneself, the injection speed is stable, and the sampling accuracy is high;

The sampling system that combines positive and negative pressure can achievesample degassing and is suitable for testing products with different viscosities;

Built-in pressure sensor, built-in air purification system in the host;

A variety of sampling containers can be used;

7-inch color touch screen, supports Chinese and English dual interface;

Built-in multiple calibration curves, compatible with all commonly used domestic and foreian standards for calibration;

Built-in more than ten common standards such as GJB-420A,GJB-420B, NAS1638.GB/T14039.IS04406.SAE4059CPC, SAE4059F,SAE749D,FOCT17216,QC/T29104, JB/T9737,DLT432, HH005-2018, etc., and supports custom standards Testing, built-in data analysis system;

Can carry out cleaning detection, pre-set the target cleaning requirement particle concentration, display the cleaningstatus in real time during the cleaning process, and automatically stop when the requirements are met;

The particle size can be set arbitrarily, with nearly 10.000 built-in particle sizes for easy particle size analysis:Has RS232 interface, supports 485 communication, and supports U disk storage method: According to customer needs, up to 64 detection channels can be set up at the same time:Have more than 5 account settings and individually set operator permissions.


Main Technical Parameters

Model

LPC-L2

Light Source

A semiconductor laser

Particle Size Range

0.8μm~600μm (calibrated according to ACFTD calibration 1~100μm or ISO MTD calibration 4~70μm(c))

Detection Channel

8~64 channels are optional (factory default 64), and the particle size can be set arbitrarily

Sensitivity

0.8μm (ISO4402) or 3μm (c) (GB/T18854, ISO11171)

Resolution

<10% (GB/T18854, ISO11171)

Repeatability

RSD<2%

Sample Testing Viscosity

≤650cSt (excessive viscosity can be detected with heating or dilution methods)

Sampling Volume

0.2~6000mL,interval 0.1mL

Sampling Accuracy

≤±0.5%

Sampling Speed

5~80mL/min

Pressure Chamber

Positive and negative pressure chamber devices enable sample degassing and high-viscosity sample detection

Maximum Vacuum Of Pressure Chamber

-0.08Mpa

Maximum positive pressure of air pressure chamber

0.8 Mpa

Maximum Particle Concentration

12000-40000 capsules/mL

Detect Sample Temperature

0℃~80℃

Working Temperature

-20℃~60℃

Storage Temperature

-30℃~80℃

Power

110~245V AC、50/60Hz, 70W

Host Size

340mmx410mmx650mm

Air Pump Size

180mmx160mmx220mm

Host Net Weight

>23kg Air pump net weight: >5.5kg