Pen Testers
Product Description
1.Probes replaceable, meeting different applications.
2.Different color backlight display mode, easy to read data in different modes.
3.Data reading indicator and automatic data locking when the reading is stable.
4. Low voltage indication.
5. Buffer solutions: CH, USA, NISTstandards are selectable.
6. Auto shut off time, customized backlight display time.
7. Supplied with standard solution, sample vials and lanyard for convenient field test.
8.Protection class: IP67.
Main technical parameters
Model | PH | ORP | Cond | pH/Cond | ||
pH | Measurement range | (-2.00~16.00)pH | ✓ | - | - | ✓ |
Resolution | 0.1/0.01 | ✓ | - | - | ✓ | |
Accuracy | ±0.01pH±1 digit | ✓ | - | - | ✓ | |
Calibration points | 1-3 points | ✓ | - | - | ✓ | |
ATC range | 0-60°C(32~140°F) | ✓ | - | - | ✓ | |
ORP | Measurement range | (-1000.0~+1000.0)mV | optional | ✓ | - | ✓ |
Resolution | 0.1/1 | optional | ✓ | - | ✓ | |
Accuracy | ±0.1%F.S ±one digit | optional | ✓ | - | ✓ | |
Conductivity | Measurement range | 0~19.99mS/cm, Auto~ranging:0~19.99μS/cm;20.0~199.9μS/cm; 200~1999μS/cm;2.00~19.99mS/cm TDS:0.0mg/L~10.0g/L(TDS factor adjustable) Resistivity:50Ω • cm~20ΜΩ· cm Salinity:0~10ppt | - | - | ✓ | ✓ |
Resolution | 0.01/0.1/1 | - | - | ✓ | ✓ | |
Accuracy | ±1.0%F.S ±one digit | - | ✓ | ✓ | ||
Temperature | Measurement range | 0-60°C(32~140°F) | ✓ | ✓ | ✓ | ✓ |
Resolution | ±0.2℃ | ✓ | ✓ | ✓ | ✓ | |
Test Kit | Meter | ✓ | ✓ | ✓ | ✓ | |
Probe (pre-installed) | PH1-S | ORP1-S | EC1-S | PC1-S | ||
pH buffer solution:pH4.00/7.00/10.01,30mL/each | ✓ | - | - | - | ||
3.0 mol KCl pH/ORP soaking solution:10mL,1 bottle | ✓ | ✓ | - | ✓ | ||
Sample Vials:30mL | 3 | 1 | 2 | 4 | ||
Standard ORP solution:222 mV,30mL | - | ✓ | - | - | ||
Standard Cond solution:1413μS/12.88mS/cm 30mL/each | - | - | ✓ | ✓ | ||
pH buffer solution:pH4.00/7.00,30mL/each | - | - | - | ✓ | ||
4×1.5V AAA alkaline batteries(pre-installed) | ✓ | ✓ | ✓ | ✓ | ||
Lanyard | ✓ | ✓ | ✓ | ✓ | ||
Hard carrying case(L/W/H: 28.0×23.0×8.2cm) | ✓ | ✓ | ✓ | ✓ | ||