Nano-100/300/400A/500 Micro-Spectrophotometer
Description
Nano-100 Micro-Spectrophotometer
Nano-100 is a micro-spectrophotometer with full wavelength (200-800 nm). It can quickly and accurately detect the sample concentration. Because it is easy to use, less consumption of samples (only 2 μL), no preheating, can quickly clean up residual samples, samples do not need to dilute and other characteristics, has become a routine instrument in many laboratories.
Features:
1. Full wavelength (200~800 nm) micro-spectrophotometer
2. Direct detection of high concentration samples without dilution, maximum detection concentration up to 4500 ng/μL (dsDNA)
3.High resolution CCD array detector, 5 s can complete the detection, display the results
4. Need to connect PC computer to run detection, data saving, printing, sorting are very convenient
5. Long life pulse xenon lamp light source
Nano-300 Micro-Spectrophotometer
With full wavelength (200-800 nm). It added a function of bacterirum cell concentration detection (OD 600) . Equipped with the cuvette mode to measure the concentration of bacteria and other culture media, so as to estimate count the growth of bacteria.
1. Android system, 7-inch capacitive touch screen.
2. Newly designed OD600 optical path detection system, new cuvette mode.
3. High resolution CCD array detector, 5 s can complete the detection, display the results.
4. With its own high-definition touch screen and control program, without a computer connection.
5. Long life pulse xenon light source, intelligently identify the user's usage. No operation within 5 minutes, the light source will be automatically turned off to prolong the service life.
6.With USB; Can print reports directly through the built-in printer.
Automatic detection and automatic blank function
Nano-400A Ultra-micro Nucleic Acid Analyzer
Nano-400A ultra-micro nucleic acid analyzer is an instrument used to detect the concentration and purity of DNA and RNA. The sample size required for each measurement is only 1.0 to 2 μL. Without accessories such as cuvettes or capillaries.
Features:
1.Ultra-micro nucleic acid analyzer with fixed wavelength (260 nm, 280 nm, 365 nm) .
2. Android system, 7-inch capacitive touch screen, no computer connection required.
3. LED light source.
4. It is mainly used to detect the concentration and purity of nucleic acid.
5. Newly designed OD600 optical path detection system, new cuvette mode, convenient for the concentration detection of bacteria, microorganisms and other culture solutions.
6. The test data is transferred to the computer via USB.
7. The built-in printer can print the report directly.
Nano-500 Micro-Spectrophotometer
With a sample size of only 0.5 μL to 2 μL, can be rapidly and accurately detected.
The cuvette mode can be used to detect the concentration of culture media such as bacteria
Features:
1.Added fluorescence detection function, can accurately measure DNA samples below 5 ng/μL. With the corresponding detection kit, the detection limit can reach 0.5 pg/μL (dsDNA). able to accurately quantify the concentration of DNA, RNA and protein through the specific binding of fluorochrome with target material, and the minimum limit is 0.5 pg/μL (dsDNA).
2.Standard OD600 detection function.
3.Android system, 7-inch capacitive touch screen.
4.High-resolution CCD array detector, 6 s can complete detection and display results.
5.Long life pulse xenon lamp light source.
6.With USB;The built-in printer can print the data directly.
Main Technical Parameters
Model | Nano-100 | Nano-300 | Nano-400A | Nano-500 |
Wavelength Range | 200-800 nm | 200-800 nm | 260 nm, 280 nm | 200-800 nm |
Minimum Sample Size | 0.5-2.0 μL | 0.5-2.0 μL | 1.0-2.0 μL | 0.5-2.0 μL |
Path Length | 0.2mm,1.0mm | 0.2mm,1.0mm | 0.5mm | 0.05/0.2mm,1.0mm |
Light Source | Xenon flash lamp | Xenon flash lamp | UV LED | Xenon flash lamp |
Detector Type | 2048-linear CCD array | 2048-linear CCD array | UV-silicon photocell | 2048-linear CCD array |
Wavelength Accuracy | 1nm | 1nm | - | 1nm |
Spectral Resolution | ≤3 nm | ≤3 nm | ≤8 nm | ≤3 nm |
Absorbance Precision | 0.003 Abs | 0.003 Abs | 0.005 Abs | 0.003 Abs |
Absorbance Accuracy | 1% (7.332 Abs at 260 nm) | 1% (7.332 Abs at 260 nm) | 2% (7.332 Abs at 260 nm) | 1% (7.332 Abs at 260 nm) |
Absorbance Range | 0.04~90 A | 0.04~90 A | 0.2~50 A | 0.04~300 A |
Nucleic Acid Detection Range | 2~4500 ng/μL (dsDNA) | 2~4500 ng/μL (dsDNA) | 10-2500 ng/μL (dsDNA) | 2~15000 ng/μL (dsDNA) |
Measurement Time | <5s | <5s | <6s | <6s |
Dimension (WxDxH) mm | 200×250×166 | 210×268x181 | 208×280×186 | 208×320×186 |
Weight | 2.6 kg | 2.8 kg | 2.0 kg | 3.6 kg |
Sample Pedestal Material | Aluminum alloy and quartz fiber | Aluminum alloy and quartz fiber | Aluminum alloy and quartz fiber | Aluminum alloy and quartz fiber |
Operating Voltage | DC24 V2A | DC24 V2A | DC24 V2A | DC24 V2A |
Operating Power | 20W | 25W | 25W | 25W |
Standby Power | 5W | 5W | 5W | 5W |
Software Compatibility | Win 7, Win XP, Win 8 | Android system | Android system | Android system |
Cuvette Mode (OD600 measurement) | ||||
Light Source | - | LED | LED | LED |
Wavelength Range | - | 600±8 nm | 600±8 nm | 600±8 nm |
Absorbance Range | - | 0-4Α | 0-4Α | 0-4Α |
Fluorometer Mode | ||||
Sensitivity | dsDNA: 0.5 pg/μL | |||
Linear Dynamic Range | R²≥0.995 | |||
Repeatability | ≤1.5 % |